Products Category
Home > MicroscopeTool Microscope > MIC-19JPC-V microscope

Universal Tool MicroscopeImage19JPC-V

19LPC-V image-type all-purpose tool microscope is a new added image measuring system on the base of preserving all-purpose tool microscope performance. This system uses vision and special-purpose optical objective to substitute human’s eye to collimate and save video graph. Adopting electronic magnifier its zoom multiple is greatly improved and it is convenient to observe small work piece and precisely measure. Depending on high-precision track of all-purpose tool microscope, this system may realize high-precision image measuring in real meaning.

 

Image measuring parts optical objective lens

magnification

Total magnification

Objective view field

Working distance(mm)

3x

25x

Φ6

110

5x

37x

Φ4

95

Whole set of instrument

      1. Mainframe: digital all-purpose tool microscope 19JC

      2. Data gather

      3. Planar measuring software

      4. Brand computer and HP color ink-jet printer

      5. Image measuring groupware (lifting arm, video-cam., and graph catcher)

      6. Image measuring software

 

1. Main technical specification of universal tool microscope

      Measuring range and division value        X-Y-coordinate 

Measuring range 200×100   Division value    0.0005

      Collimation microscope     Lifting distance:120mm

      Arm of force inclining range: both 15°left and right   Division value 10′

      Illumination grating adjusting range: φ3φ32   Division value1

      Clinometers eyepiece  Angle measuring range: 360°  Division value  1′

      Figure eyepiece   Angle measuring range: ±7°  Division value10′

                      Circulate arc recircle   Curvature radius: R0.1100

                      Screw recircle   Common screw distance t = 0.25 - 6

                                      Trapezium screw distance T = 2 - 20

      Optical indexing table Measuring range: 360° Division value10″(projected value)

      (Optional)  Diameter of glass table φ106

      Optical dividing head  Measuring range: 360°Division value1′

      Optical localizer   Diameter of measuring headφ3±0.1

                      (Actual high-point diameter error can not more than 0.5μm.)

                      Measuring force   8 -14g

                      Max. measuring depth  15

      Glass worktable   Glass worktable dimension: 215×130

      Thimble bracket   Max. clamping diameterφ100

                      Max. clamping length: diameter of tested part≤ 55,750mm

                                        diameter of tested part 55,600mm

      High thimble bracket Max. clamping diameter: φ180

                        Max. Clamping length:600mm

      V-type bracket: 

Left V-type bracket front and behind adjusting range: Both5mmfront and behind.

      Right V-type bracket upper and downward adjusting range: Upper15mm/ Downward3mm

      Max. Carrying Capacity:40kg

2. Optical parameter of collimation microscope

Tag value of objective’s zoom multiple

1x

3x

5x

Total zoom multiple

Clinometer or figure eyepiece

10x

30x

50x

Double-image eyepiece

15x

42x

65x

Field of view(mm)

Clinometer or figure eyepiece

φ20

φ6.6

φ4

Double-image eyepiece

φ13

 

φ4.7

φ3

Working distance(mm)

Clinometer or figure eyepiece

81

90

65

Double-image eyepiece

47

85

63

3. Instrument precision

 Temperature requirement (1) Workroom temperature should be 20 ±2 ℃.

                     (2)Workroom temperature change can not exceed1 ℃per hour.

                      (3)Tested part and instrument temperature difference can not exceed0.5 ℃.

 In the condition of meeting all temperature requirements, the instrument has the following guarantee:

(1)X-Y-coordination: When using glass millimeter ruler to examine, the Max. Un-precision of the instrument is (1 + L / 100μm. L: Measuring length. Unit is mm

                   When the ruler corrects according to correction table, X-direction can not be more than 0.0035. Y-direction can not be more than 0.0025.

  (2) Clinometers eyepiece: Max. un-precision: not more than 1′.

  (3) Double-image eyepiece:  Instability of imaging: not more than 0.0005

                          Incorrectness of imaging: not more than 0.001.

  (4)Optical dividing head: Max. un-precision: not more than 1′.

  (5)Optical indexing table: Max. un-precision: not more than 30″ (optional).

  (6)Optical graduator: Instability of measuring: not more than 0.001.

                   Incorrectness of measuring: not more than 0.0015

4. Weight of instrument and overall dimension

      Mainframe net weight: 250kg

      Overall dimension: L ×W × W):980 ×1020 ×640 mm