Freezing Microtome MIC-335III
Product Feature :
• Adopted Germany Stepper motor drive ensure slice more precisely ,more reliable and quiet.
• The LCD screen shows slice and trimming thickness ,section counter ,keyboard with controls for thickness, mode and speed
• Special function of specimen retraction which avoid the damage due to the attrition between sample and the back of knife so that the sectioning is more smooth and the life of the knife is more longer .
• The hand wheel can be locked in any position to ensure the sectioning as safe and convenient as possible
• The waste tray can be disassembled easily
• Sample orientation:8°along the X-Y-axis, rotate 360°
• Safety alarm system , overload protection function, sleep mode protection
Universal cassette clamp and standard specimen clamp
Technical Data
• Section thickness range: 0- 100um
Setting values :
from 0-10 um in 1 um –increments
Form 10-20um in 2um-increments
Form 20-50 um in 5um-increments
Form 50-100um in 10 um-increments
• Trimming section thickness range :0-500um
• Horizontal specimen stroke :28 mm
• Vertical specimen stroke : 60mm
• Specimen retraction :12um
• Precision error: ± 5%
• Maximum section size: 50 × 45mm
• Dimension : 520 x 450 x 300mm
• Net weight:30kg
MIC-III Freezing system
Product Description
The system is extensively used at hospital, epidemic prevention, agriculture, forestry and other scientific research institutions. It make up with advanced third computerized thermostatic power semiconductor refrigeration, Cryo-Scalpel, Cryo-console. The power is made of advanced nanometer material, it has the characteristics of light, no noise. The LCD display can show the temperature of the Cyro-scalpel and Cryo-console at the same time.
The system have the characteristics of working evenly, freezing fast, and operating easily, stably and conveniently. It can avoid the position that it is difficult to control the temperature of the Cryo-console and Cryo-scalpel so that it will damage the tissue and hade to analys it. The angle between Cryo-console and Cryo-scalpel is 45° which made the tissue attached to the slice easily.
In addition to rapid freezing slice, the system is also can regular paraffin slice.
Technical Data:
1)Slice thickness range: 1-60micron(335III,MIC-315III, MIC -355ATIII)
1-35micron (2508 III )
1-30micron(1508A III / 1508RIII /2508 III)
1-25micron (202AIII /202 III / 2508 III)
2) Least slice adjusting graduation: 1micron
3)Maximum slice section: 40 × 50μ M 40 × 30μ M
4)Maximum cold storage area: 40 × 32 μ M
5) LCD display show the temperature of Cryo-console and Cryo-scalpel simultaneity
6)maximum difference in temperature of freezing stage ≥ 60℃
7)maximum difference in temperature of cooling knife ≥ 50℃
8)automatic recovery of refrigeration working state after defrost
9)After automatic defrost, it takes 4-8 minutes to reach setting temperature