Freezing Microtome MIC-335III

Product Feature :

Adopted Germany Stepper motor drive ensure slice more precisely ,more reliable and quiet.

The LCD screen shows slice and trimming thickness ,section counter ,keyboard with controls for thickness, mode and speed

Special function of specimen retraction which avoid the damage due to the attrition between sample and the back of knife so that the sectioning is more smooth and the life of the knife is more longer .

The hand wheel can be locked in any position to ensure the sectioning as safe and convenient as possible

The waste tray can be disassembled easily

Sample orientation:8°along the X-Y-axis, rotate 360°

Safety alarm system , overload protection function, sleep mode protection

Universal cassette clamp and standard specimen clamp

Technical Data

Section thickness range: 0- 100um

Setting values :  

from 0-10 um in 1 um increments                  

Form 10-20um in 2um-increments

Form 20-50 um in 5um-increments

Form 50-100um in 10 um-increments

Trimming section thickness range :0-500um

Horizontal specimen stroke :28 mm

Vertical specimen stroke : 60mm

Specimen retraction :12um

Precision error: ± 5%

Maximum section size: 50 × 45mm

Dimension : 520 x 450 x 300mm

Net weight30kg

 

 

MIC-III Freezing system

Product Description

The system is extensively used at hospital, epidemic prevention, agriculture, forestry and other scientific research institutions. It make up with advanced third computerized thermostatic power semiconductor refrigeration, Cryo-Scalpel, Cryo-console. The power is made of advanced nanometer material, it has the characteristics of light, no noise. The LCD display can show the temperature of the Cyro-scalpel and Cryo-console at the same time.

The system have the characteristics of working evenly, freezing fast, and operating easily, stably and conveniently. It can avoid the position that it is difficult to control the temperature of the Cryo-console and Cryo-scalpel so that it will damage the tissue and hade to analys it. The angle between Cryo-console and Cryo-scalpel is 45° which made the tissue attached to the slice easily.

In addition to rapid freezing slice, the system is also can regular paraffin slice.

Technical Data:

1)Slice thickness range: 1-60micron(335III,MIC-315III, MIC -355ATIII)

1-35micron (2508 III )

1-30micron(1508A III / 1508RIII /2508 III)

1-25micron (202AIII /202 III / 2508 III)

2) Least slice adjusting graduation: 1micron

3)Maximum slice section: 40 × 50μ M 40 × 30μ M

4)Maximum cold storage area: 40 × 32 μ M

5) LCD display show the temperature of Cryo-console and Cryo-scalpel    simultaneity

6)maximum difference in temperature of freezing stage 60

7)maximum difference in temperature of cooling knife 50

8)automatic recovery of refrigeration working state after defrost

9)After automatic defrost, it takes 4-8 minutes to reach setting temperature